Commissioned as a glass or dishwasher on install. As a glasswasher the 400 x 400mm basket can hold 16 pint-sized glasses and wash up to 640 glasses per hour. As a dishwasher the basket can hold nine dinner plates and wash up to 270 plates per hour.
The C400 comes complete with a drain pump, rinse booster pump and detergent and rinse aid pumps with a double skinned door and cabinet to reduce noise and limit heat loss.
Inside, the C400 has new click in, click out wash arms, a new double filtration system, and new moulded wash tank and basket rails, all enhancing wash results and making the machine simple to clean. Reduced rinse water consumption and detergent usage.
Dimensions
460 mm x 570 mm x 720 - 750 mm
Basket Size
400 x 400 mm
Suitable for 355 x 435 mm glass backets
Standard Equipment
Detergent and rinse aid pumps
Programmes
1.5 & 2 min Glass / 2, 3 & 5 min Dish
Dimensions
460 mm x 570 mm x 720-750 mm
Racks / hours
Glass 40 , Dish 30
Power
20 amp 3 phase optional 15 amp single phase
Width: 460 mm
Height: 720-750 mm
Depth: 570 mm
Entry Height: 312 mm
Drain Size: 40 mm
Basket Size: 400 mm x 400 mm
Glasses per rack: 16
Plates per rack: 9
Wash Programmes - Glass: 1.5 & 2 min. cycles
Wash Programmes Dish: 2, 3 & 5 min. cycles
Theoretical max. Racks per hour - Glass: 40
Theoretical max. Racks per hour - Dish: 30
Wash Tank Capacity: 9.5 litres
Rinse Tank Capacity: 6.5 litres
Wash Temperature: 60 °C
Rinse Temperature - Glass 70 °C
Rinse Temperature - Dish: 82 °C
Water Consumption per Cycle: 2.75 litres
Hydraulic specifications
Water supply connection: G3/4” (3/4” BSP)
Required water pressure min/max: 1-10 bar
Incoming water temperature min/max: 4 °C / 55 °C
Drain size: 40mm diam.
Maximumn drain height(from machine base): 500mm)
Optional integrated water softener: Yes
Electrical specifications
15 Amp – 1 Phase
Amps Required: 15 A (1 Phase)
Standard operating voltage: 220 – 240V 1N ~ / 50Hz
Total connected load: 2.5 kW
30 Amp – 1 Phase
Amps Required: 30 A (1 Phase)
Standard operating voltage: 220 – 240V 1N ~ / 50Hz
Total connected load: 6.5 kW
15 Amp – 3 Phase
Amps Required: 15 A (3 Phase)
Standard operating voltage: 380 – 415V 3N ~ / 50Hz
Total connected load: 6.5 kW
Additional Info
Service: Installation